Parker FilterTec™ Automated Laboratory Normal Flow Filtration Systems

Single Use Assembly Benefits

Key Features

  • Safe walk-away system operation for reduced manual oversight
  • Real-time data collection of 15 filtration parameters
  • Increased normal flow filtration (NFF) efficiency—up to 30%
  • R/P Stat Method for automatic transition from constant rate to constant pressure
  • Compatible with all filter types for maximum flexibility
  • The optional scale enables gravimetric control and real-time weight-based monitoring
  • 3 pressure sensor connections to support serial or parallel filter trains
  • End-point controls for automated system shutdown at defined filtrate or pressure limits

FilterTec™ Plus – Enhanced Throughput & Statistical Verification

  • Triple your NFF productivity with parallel testing of three filters
  • Supports three pump heads and communicates with up to three electronic balances
  • Enables simultaneous testing of three identical filters or three different filters under the same pressure
  • Facilitates statistical validation of filter performance and capacity during scale-up

Optimised Filtration Control with R/P Stat Method

  • Starts filtration at a constant pump rate until the user-defined pressure is reached
  • Automatically shifts to constant pressure mode, adjusting flow to maintain consistent pressure
  • Continues until a minimum filtrate flow rate is reached, ensuring maximum filter utilisation
  • Delivers up to 30% higher throughput compared to constant flow or pressure methods

Advanced Filterability Studies

  • Simultaneous monitoring of three pressure points allows evaluation of serial or parallel filter trains
  • Detects pressure build-up to guide pore size or filter area adjustments
  • Programmable R/P mode allows stair-step or ramped changes in pump rate or pressure over time
  • Ideal for filter size determination and process development

Vmax Determination for Predictive Performance

  • Collects filtrate weight under constant rate, pressure, or R/P Stat modes
  • Calculates and documents Vmax by plotting Time / Filtrate Weight
  • Instantaneous Vmax is reported from real-time slope changes in filtration data
  • Supports accurate filter sizing and capacity forecasting

Single Use Assembly Technical Data

Description
Dimension / Weight Width: 5.75″ (146 mm) x Height: 8.5″ (2126 mm) x Depth: 11″ (279mm): 14 lbs (6.4 Kg)
Enclosure & Rating 16 Ga, aluminium baked epoxy blue 4-40dC, 0-100% humidity
Pressure Sensors Accommodates up to three disposable pressure sensors. The calibrated pressure range is 0-60 psi.
Any point within this range can be recalibrated using an external pressure reference source.
Power 115 / 220-240 VAC, 60/50 Hz, 75 Watts, double-fused: T1AL 250V (CE: IR35A 250VAC)
Motor / Encoder 8, 160, 600 RPM, 30 VDC, 3.8A, 120 ppr 8 and 160 RPM, 100 ppr 600 RPM
I/O Ports Male DB9 scale connections (RS-232), female DB9 printer or PC Connection (RS-232), external ISO
DB37 connector, 1 TTL input, 4 TTL output, 3 4-20mA
Operational Mode Constant rate (can be used to perform R/P stat method), constant pressure, R/P programmable, and
manual mode